Product applications

  • Foundations/Below ground level (DPC)
  • Solid walls

Compressive Strength

3.6N/mm2, 7.3N/mm2

Thermal Conductivity

0.24W/mK*, 0.29W/mK*

Density

600kg/m3, 730kg/m3

*Please note that the thermal conductivity quoted for use below ground is different to that when used above DPC, because they may have higher moisture content.

More Information
BrandCelcon
Depth300mm

300mm Celcon Foundation (Trench) Block 3.6N/mm2

 
MPN Code
SFC300/40
Part Code
B30504

Offering beneficial thermal performance, they are suitable for the support of cavity or solid walls, framed construction or suspended floors, including beam and block floors. They are resistant to damage caused by water penetration.

With exceptional resistance to freeze/thaw conditions and sulfate attack when they occur below ground level: BBA certificate 01/3816 confirms that all Celcon Foundation Blocks are suitable for use in soil conditions from DS1 to DS4.

Celcon Foundation Blocks can be laid below ground level without mortar perpends. Simply lay them with mortared horizontal bed joints and then butt them together to prevent the passage of vermin.

All Celcon Foundation Blocks may also be used above ground, with appropriate finishes, for solid wall construction.

 
In stock
£6.84 £5.70
Sold by / Each
In Stock
Bulky Item
Collection from store

Collection from our branches at Kingsfold and Billingshurst. You can choose a collection date/time at checkout.

Local Delivery

Delivery by our own vehicles around Surrey and Sussex. Available delivery dates shown at checkout. Please see Delivery Information for costs.

Can we deliver to your location?

Add for Delivery
Delivery date selectable at checkout
Click & Collect
1021 Stock Available

Offering beneficial thermal performance, they are suitable for the support of cavity or solid walls, framed construction or suspended floors, including beam and block floors. They are resistant to damage caused by water penetration.

With exceptional resistance to freeze/thaw conditions and sulfate attack when they occur below ground level: BBA certificate 01/3816 confirms that all Celcon Foundation Blocks are suitable for use in soil conditions from DS1 to DS4.

Celcon Foundation Blocks can be laid below ground level without mortar perpends. Simply lay them with mortared horizontal bed joints and then butt them together to prevent the passage of vermin.

All Celcon Foundation Blocks may also be used above ground, with appropriate finishes, for solid wall construction.